Alarm SAF RMBE Series Installationshandbuch

Stöbern Sie online oder laden Sie Installationshandbuch nach Elektrische Gehäuse Alarm SAF RMBE Series herunter. Alarm SAF RMBE Series Installation manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - MiniBay E-911

031-171-C0-003 Rev. C 1MiniBay E-911Enclosure Installation ManualEffective: October, 2004RMB-E-911-A48RMB-E-911-CRMB-E-911-B®Alpha TechnologiesRadiu

Seite 2 - Alpha Technologies

10 031-171-C0-003 Rev. CBattery Safety Notes, cont.• Neutralize any spilled battery emission with the special solution contained in an approved spill

Seite 3 - 1-800-863-3364

031-171-C0-003 Rev. C 11Recycling and Disposal InstructionsSpent or damaged batteries are considered environmentally unsafe. Always recycle used batt

Seite 4 - Table of Contents

12 031-171-C0-003 Rev. C1.0 Overview and Specifications1.1 The MiniBay E-911 Series EnclosuresThe Federal Communications Commission (FCC) created the

Seite 5 - List of Figures

031-171-C0-003 Rev. C 13Intrusion alarmswitchAlarm InterfaceGround BarInput 48VDC (+)and (-)Roxtec Panel1.0 Overview and Specifications, cont.19"

Seite 6 - Document Revision History

14 031-171-C0-003 Rev. C1.2 RMB-E-911 System Specifications1.2.1 RMB-E-911-A48 PartRadium MiniBay RMB-E-911-A48 Specifications NumberRadium MiniBay

Seite 7 - Symbols in this Manual

031-171-C0-003 Rev. C 151.2 RMB-E-911 System Specifications, cont.1.2.2 RMB-E-911-BRadium MiniBay Specifications Part Number(24V) RMB-E-911-BRadium M

Seite 8 - General Safety Precautions

16 031-171-C0-003 Rev. C1.2 RMB-E-911 System Specifications, cont.1.2.3 RMB-E-911-CRadium MiniBay RMB-E-911-C Specifications Part NumberRadium MiniBa

Seite 9 - Battery Safety Notes

031-171-C0-003 Rev. C 17POS(+)NEG(-)20AEnclosure GroundFront and RearTamper Switches31-32 Tamper27-28 Converter FailAir ConditionerCustomer Supplied-

Seite 10

18 031-171-C0-003 Rev. C1.3 System Wiring Schematics, cont.1.3.2 ‘B’ ConfigurationRadium MiniBays arrive at their destination with all internal compo

Seite 11 - Mechanical Safety

031-171-C0-003 Rev. C 19POS NEG20A48VDC Input24VDC OutputEnclosure Ground24VDC Breaker PanelFront and RearTamper Switches31-32 Tamper27-28 Converter

Seite 12

2 031-171-C0-003 Rev. CPowerAlpha Technologies®

Seite 13 - 031-171-C0-003 Rev. C 13

20 031-171-C0-003 Rev. C2.0 Site Preparation2.1 General InformationDescriptionThis document describes the installation procedures for the RMB-E-911-B

Seite 14 - 1.2.1 RMB-E-911-A48

031-171-C0-003 Rev. C 21Fig. 2-1, Swing Arc of Enclosure door31.0"43.0"37.0"63.0"35.0"Top of Enclosure w/Door OpenTop of Enc

Seite 15 - 1.2.2 RMB-E-911-B

22 031-171-C0-003 Rev. CFig.2-3, Pad Dimensions for Single-wide Enclosure3” H X 42” W X 44” DP/N 641-110-10Fig. 2-2, Polymer Precast Pad for Single-w

Seite 16 - 1.2.3 RMB-E-911-C

031-171-C0-003 Rev. C 2325.82"/65.58cm25.00"/63.5cm4.00"/10.16cmRearFrontWhen placing the pad, allow at least 40” of clearance for the

Seite 17 - 1.3.1 ‘A48’ Configuration

24 031-171-C0-003 Rev. CEnclosure Footprint2feet(min)Connection made with Burndy connector(P/N YGHR58C2W-3 orequivalent)Connection made with Burndy c

Seite 18 - 1.3.2 ‘B’ Configuration

031-171-C0-003 Rev. C 25DX2=64"D=32"DO NOT lift the enclosure with the batteries in place.• Do not transport, lift, or place the unit on an

Seite 19 - 1.3.3 ‘C’ Configuration

26 031-171-C0-003 Rev. C3.0 Installation, cont.3.2 Enclosure InstallationThe RMB-E-911 is provided with either a 7” riser or 14” riser/battery module

Seite 20 - 2.0 Site Preparation

031-171-C0-003 Rev. C 273.0 Installation, cont.3.2 Enclosure Installation, cont.Installation Procedure, ‘B’ ConfigurationRemove all packing material

Seite 21 - 2.3 Site Selection

28 031-171-C0-003 Rev. C3.3.1 Basic Theory of Refrigeration:1. Low pressure gas is drawn into the compressor pump, and compressed into a high pressur

Seite 22

031-171-C0-003 Rev. C 29Fig. 3-3, Air Conditioner Control Board3.0 Installation, cont.3.3.2 Air Conditioner Control BoardThe air conditioner control

Seite 23 - 4.00"/10.16cm

031-171-C0-003 Rev. C 3Power SystemsMiniBay E-911 Enclosure Installation Manual031-171-C0-003 Rev. C — © 2004 Alpha TechnologiesContacting Alpha Tec

Seite 24 - Enclosure Footprint

30 031-171-C0-003 Rev. C3.0 Installation, cont.3.3.3 Air Conditioner Temperature Control Card Wiring Diagram24 or 48 VDCModel SpecificMAJOR ALARM CON

Seite 25 - 3.0 Installation

031-171-C0-003 Rev. C 3150°F/10°C59°F/15°C68°F/20°C77°F/25°C86°F/30°C95°F/35°C104°F/40°C40° C Maximum Internal Temp.38° C Startup34° C Shutdown38° C

Seite 26 - 3.2 Enclosure Installation

32 031-171-C0-003 Rev. Cmax 8 Nm1234567891011The Roxtec block panel is designed to allow rotation, as shown below. It can also be moved to theopposit

Seite 27

031-171-C0-003 Rev. C 332 19" Swing-Awayequipment rack1 Securing Bolt1 Securing Bolt3 EnclosureGround BarFig. 3-5, 19” Swing Rack (RMB-E-911

Seite 28 - 3.3 Air Conditioner Overview

34 031-171-C0-003 Rev. C3.0 Installation, cont.3.6 Battery Installation (RMB-E-911-B)1 Remove the front battery enclosure cover and set aside.2 Slide

Seite 29 - 704-713

031-171-C0-003 Rev. C 3524VDC Input+24VDC Output #1Enclosure GroundBar (24VDC Neg)Fig. 3-7, 24VDC Connections (RMB-E-911-C)3.0 Installation, cont.3.7

Seite 30 - 3.0 Installation, cont

36 031-171-C0-003 Rev. C3.0 Installation, cont.3.8 Service Power Connections (RMB-E-911-B)The service power breaker box is located in the rear of the

Seite 31 - 18° C Setpoint

031-171-C0-003 Rev. C 37Enclosure GroundBar48VDC Input BarRoxtec PanelFig. 3-9, 48VDC Connections (RMB-E-911-C and -A-48)3.0 Installation, cont.3.9 4

Seite 32

38 031-171-C0-003 Rev. C®USC®NRTL/C®CUSCSA International (CSA) was established in 1919 as an independent testing laboratoryin Canada. In 1994, OSHA g

Seite 33

Due to continuing product improvements, Alpha reserves the right to change specifications without notice.Copyright © 2004 Alpha Technologies, Inc. All

Seite 34

4 031-171-C0-003 Rev. CPower SystemsTable of ContentsDocument Review History...

Seite 35 - Bar (24VDC Neg)

031-171-C0-003 Rev. C 5Power SystemsList of Figures1.0 Overview ...

Seite 36 - 36 031-171-C0-003 Rev. C

6 031-171-C0-003 Rev. CDocument Revision HistoryDocument Name Control/Rev. Number Release DateRadium MiniBay E-911 031-171-C0-001 Rev. AEnclosure Ins

Seite 37 - Roxtec Panel

031-171-C0-003 Rev. C 7Important Safety InstructionsReview the drawings and illustrations contained in this manual before proceeding. If there are an

Seite 38 - 4.0 Appendix

8 031-171-C0-003 Rev. CGeneral Safety PrecautionsThis enclosure and its associated hardware (power supply, batteries, cabling) may containequipment,

Seite 39

031-171-C0-003 Rev. C 9Battery Safety NotesLead-acid batteries contain dangerous voltages, currents and corrosive material. Battery installation,main